Huaxin high frequency infrared carbon and sulfur analyzer test standard
As for digital Printed Glass, Designs can be implemented in previously unattainable dimensions, with incomparable resolution and focal precision, and with unique color intensity. The end product, refined in this way, not only meets the most challenging aesthetic demands but also satisfies on a sustainable basis all functional and material requirements. Digital printing technology is ideally suited for implementing glass designs quickly, easily, and economically - both for interiors and exteriors. Glass areas can be enhanced with high-level resolution and brilliant color intensity - according exactly to customer specifications and taste. Ceramic digital printing - unlike conventional screen printing - can print a number of different colors simultaneously.
1.1 The equipment meets the determination of carbon and sulfur content in various glass materials such as metal materials.
1.2 The equipment meets the site power supply: 220V, 50Hz.
1.3 Quantity: 1 set.
2. Main technical parameters
2.1 Detection method: high frequency furnace combustion - infrared absorption method.
2.2 Measurement range: sulfur 0.00001% ~ 15%
Carbon 0.00001% to 20%
2.3 Minimum reading: 0.00001%.
2.4 Sensitivity: 0.1ppm.
2.5 Measurement error: sulfur RSD ≤ 1.0% in line with IS04935 international standard.
Carbon RSD ≤ 0.5% in line with IS09556 international standard.
2.6 Measuring cell: measure the sulfur pool, measure the carbon pool.
2.7 Analysis time is 20s ~ 100s and adjustable.
2.8 high frequency furnace
1) Oscillation frequency: 20MHz.
2) Output power: >2.5KVA and adjustable.
3) The high frequency furnace is suitable for combustion analysis of various samples.
2.9 Top oxygen flow rate: 1.0 L/min ~ 2.0L/min.
2.10 Analyze gas flow: 3.0 L/min to 4.5 L/min.
2.11 The equipment comes with an oxygen purification device.
2.12 Circuit Design
1) The whole machine adopts dual CPU upper and lower position machine modular design, and the electronic circuit requires high integration and stability.
2) Infrared detection and high frequency furnace are connected by anti-interference fiber.
3) The device has automatic outdated and overcurrent alarm functions.
2.13 Infrared detection power supply selects the industrial grade integrated linear module power supply with stable output.
2.14 High-precision electronic flow controller ensures airflow stability and air intake system for intake ports (including solenoid valves, pipe joints and lifting cylinders)
Automatic leak detection.
2.15 Light source: A new platinum infrared source.
2.16 Detector: gold-plated carbon-sulfur analysis cell and high-precision lithium niobate pyroelectric infrared detector (up to 10-11).