After Hansa generator air filter is used for a period of time, the filter core will become dirty and the filter's intake resistance will increase. When the air filter's intake resistance increases to 625KPa or more At the time, the diesel engine will suffer from problems such as premature exhaustion of black smoke and insufficient power due to lack of sufficient air supply.
The user can determine the clogging of the air filter by observing the air resistance indicator installed on the air intake pipe behind the air filter, ie when the indication window of the air resistance indicator turns from normal green to red. It indicates that the filter inlet resistance exceeds the limit value and it needs to be cleaned or replaced. In the event of air filter clogging, the air cleaner core should be immediately shut down for cleaning or replacement, and then should be reset by the rubber plug at the end of the air resistance indicator. The filter core can be cleaned by the following procedure.
1. Tap the air filter core end cap to shake off the accumulated dust on the filter core.
2. Open the dust outlet of the dust collector and let go of the accumulated dust.
3. Open the filter cover and pull the filter core out.
4. Block the two ends of the filter element with a clean cloth or rubber stopper. Then use dry compressed air with a pressure of no more than 0.2~0.3Mpa to blow the filter core surface outward along the corner of the filter core or out of the filter element.
Note: It is not allowed to clean the air cleaner core with oil or water; the swivel tube is fixed with its shell and is not removable; it can be cleaned with hot alkaline water during cleaning, and then blown with compressed air; heavy air The inner filter core of the filter cannot be cleaned.
The air filter (external) filter must be replaced when the following problems occur
1. The air filter (external) filter element has been damaged.
2. When the cleaned filter core is installed, the intake resistance indicator is again indicated in red.
3, the filter core cleaning has reached five times.
Replace the filter
1. Loosen the wing nut that secures the bottom cover to the filter housing and remove the filter cover.
2. Pull down the filter element from the center bolt.
3. Remove the gasket from the outlet end of the filter.
When installing the filter element, the filter element must be seated on the seal of the outlet end of the air cleaner.